1.
Japanese Journal of Cardiovascular Surgery ; : 29-33, 2023.
Article in Japanese | WPRIM | ID: wpr-966089

ABSTRACT

We report a case of redo mitral valve replacement (MVR) for a Björk-Shiley Delrin valve implanted 47 years previously. A 71-year-old man initially underwent MVR for mitral regurgitation at our hospital at the age of 16 years. Following the operation, follow-up examinations were performed at the outpatient clinic and annual transthoracic echocardiogram findings showed only mild mitral regurgitation, with no adverse events noted. However, a transthoracic echocardiogram examination performed 45 years after the operation revealed mild to moderate mitral regurgitation, while dyspnea with exertion was also noted at that time. As part of a more detailed examination, transesophageal echocardiogram results showed moderate transvalvular leakage. Redo MVR was subsequently performed under the diagnosis of prosthetic valve dysfunction. Analysis of the explanted prosthetic valve revealed wear of the Delrin disk, and widening of the gap between the disk and strut, which were presumed to be the cause of transvalvular leakage. A half century has passed since introduction of the Björk-Shiley valve and the present is a rare case of valve malfunction. Presented here are related details, along with a review of existing literature and results of Björk-Shiley valve use at our hospital.

2.
Japanese Journal of Cardiovascular Surgery ; : 114-117, 2022.
Article in Japanese | WPRIM | ID: wpr-924401

ABSTRACT

The patient was a 68-year-old woman who had undergone initial mitral repair at 24 years of age, and had undergone mitral replacement using the Björk-Shiley convexo-concave valve at 30 years of age. She developed exertional dyspnea 38 years after mitral replacement with hemolytic anemia. Precise examination revealed mitral stenosis and perivalvular leak. At the reoperation, severe calcified pannus was found at the ventricular side just beneath the mitral artificial valve, and made stenosis with the inadequate leaflet opening. The mitral valve remnant ring was severely calcified and the sawing ring was detached partially. Repeated valve replacement was successfully done by the reinforcement of the mitral valve ring with xenopericardium.

3.
Japanese Journal of Cardiovascular Surgery ; : 170-173, 2021.
Article in Japanese | WPRIM | ID: wpr-886203

ABSTRACT

Herein, we present a case of aortic root replacement 42 years after aortic valve replacement (AVR) with the Björk-Shiley Spherical (BSS) valve in a patient with an aortic root aneurysm. The patient was a 67-year-old man who had undergone AVR with BSS and aortic root enlargement for the treatment of infective endocarditis and aortic insufficiency at 25 years of age. He underwent aortic root replacement for an enlarged aortic root (73 mm). Under general anesthesia, median re-sternotomy was performed, and the BSS valve was removed. The valve functioned well with no pannus or thrombus. We performed an aortic root replacement using a composite graft consisting of a 24-mm mechanical valve and 30-mm artificial graft. We experienced a rare case of long-term durability of the BSS valve, which functioned well for 42 years.

4.
Japanese Journal of Cardiovascular Surgery ; : 291-294, 2020.
Article in Japanese | WPRIM | ID: wpr-825927

ABSTRACT

We encountered a case of aortic root replacement of a prosthesis-patient mismatch (PPM) after performing aortic valve replacement (AVR) with the Björk-Shiley Monostrut (BSM) valve. The patient was a 55-year-old female. She underwent AVR with a bioprosthesis for the treatment of congenital aortic stenosis at 20 years of age ; AVR was performed again using the BSM valve at 28 years of age. Congestive heart failure gradually worsened, and she was referred to our hospital at 55 years of age, where she was diagnosed with PPM after AVR. Under general anesthesia, standard median resternotomy was performed, and cardiopulmonary bypass was established with right femoral artery and right femoral vein cannulation. Cardiac arrest was achieved with the antegrade application of a cold, crystalloid, cardioplegic solution. The BSM valve was removed, and her annulus was extremely small, measuring less than 19 mm. We performed an aortic root replacement with a 21 mm mechanical valve composite graft because aortic root enlargement was difficult owing to the fragility of her annulus and very severe adhesion surrounding the ascending aorta. The postoperative course was uneventful. Postoperative ultrasonic echocardiography showed reduced transvalvular mean gradients. Although the BSM valve is durable, non-structural valvular deterioration surrounding the implanted BSM valve may occur and should be monitored.

5.
Japanese Journal of Cardiovascular Surgery ; : 247-250, 2017.
Article in Japanese | WPRIM | ID: wpr-379338

ABSTRACT

<p>We present herein a case of disc fracture of a Björk-Shiley valve prosthesis in the mitral position. A 69-year-old woman was admitted to our hospital with a sudden onset of dyspnea followed by deep shock. An echocardiography showed a severe degree of mitral regurgitation and moderate degree of tricuspid regurgitation. Forty-three years previously she had undergone a mitral valve replacement (MVR) for stenosis with the original version of a Björk-Shiley valve prosthesis in another institute. Emergency redo MVR was performed with a bioprosthesis and tricuspid annuloplasty with a semirigid ring. The disc of the extracted Björk-Shiley valve was found to have escaped from the metal housing with two intact struts. Although Björk-Shiley valve dysfunction due to Delrin disk abration has been rarely reported, complete disk fracuture is extremely rare. The important role of regular echocardiographic follow-up should be emphasized to prevent fatal valve fracture.</p>